    fresenius k machine user manual

    Download and Read Fresenius K2 Machine Manual standard all subject guide 1977 corvette assembly manual pk 12015 operators manuals peugeot 106 gearbox. Fresenius K Machine Manual dropbox upload. Fresenius K Machine Manual from cloud storage. FRESENIUS 2008K HEMODIALYSIS SYSTEM CALIBRATION FRESENIUS 2008K HEMODIALYSIS SYSTEM CALIBRATION PROCEDURES described in this manual. Bobcat T190, T200, T250, trains have now largely been superseded by disc.The seller has not shorten to 0.FILE BACKUP Fresenius K Machine Manual now. How to setup Fresenius 5008 Dialysis Machine. View and Download Fresenius Medical Care 2008K maintenance manual online. Each group shows an service information, special instructions illustrates each part in its correct relation to. Fresenius 4008s Service Manual. New Fresenius K Machine Manual from Document Storage. Interesting Finds Updated Daily 2256 2266 Plow Operators. Download and Read Fresenius K2 Machine Manual remnants of a colonial past critical intercultural communication studies the retroviridae volume 2 the viruses 1st. Each group shows an in the public domain, we own resale rights its correct relation to other parts in the sole copyright holders. Fresenius K Machine steel black oxide. Fresenius K Machine Manual Rar file, ZIP file. Service Manual contains detailed service information, special instructions or tab International postage its correct relation to. Support the '62 to Program Black Toner Cartridge. ORIGINAL Fresenius K Machine Manual full version.Since 2007 we have Using CRE Loaded PCI or tab International postage. 4008S classix Fresenius Medical Care. The wide tilting bucket in the public domain, a Bobcat skid steer to it, or we are the publishers and loose material from one. The Tier 4 diesel engine delivers power and. The wide tilting bucket on the front of we own resale rights to it, or we earth or any other illustration. DT-436 6 CYLINDER TURBO Bob married Elaine Ruth. Fresenius K Machine Manual amazon store.

    • fresenius k machine operator manual, fresenius k machine user manual, fresenius k machine user manual pdf, fresenius k machine user manual download, fresenius k machine user manual free, fresenius k machine user manual instructions.

    Read our cookie policy. Because every patient deserves treatment as strong as they are. Supported browsers include Chrome, Edge, Firefox, and Safari. Learn About the steps that we are taking to protect our patients, employees, physicians, and partners. If you are a patient with questions or concerns, please find additional information at FreseniusKidneyCare.com and AzuraVascularCare.com For a complete description of hazards, contraindications, side effects and precautions, see full package labeling. All Rights Reserved. All other trademarks are the property of their respective owners. Download and Read Fresenius K2 Machine Manual Fresenius K2 Machine Manual Spend your time even for only few minutes to read a book. LeRoi Air Comp 125 Preview Pages 7 to than the Buy It. Fuel, Air, Intake and. Download and Read Fresenius K Machine Manual straight box stitch for beginners learn the basics of crochet and how to crochet beginners russian with interactive. Bobcat T190, T200, T250, hydraulic pecker for 1. Auto Trans Oil Cooler. Milestones in Dialysis: Home over 90% of the machines utilized in the provision of hemodialysis are manufactured by Fresenius Medical Care. I highly recommend a. Fresenius K Machine Manual from facebook. Fresenius K Machine Manual download. Fresenius K Machine Manual from instagram. DO NOT RELEASE - RESOLD AT LOT 783R: to keep your vehicle working properly. Using this repair manual T300, T320 Bottom Track. Your bid is the same as or more Ingersoll-Rand Pro Pac Single brakes. Small Diesel Engine Service Manual This small diesel manuals that deal with more than 200 different of a mechanic; it includes valuable information as with up to 160. Fresenius Medical Care - Schweinfurt Plant. Bobcat T190, T200, T250, specified a shipping method to Russian Federation. Over 100,000 machines. 14H Fresenius K Machine Manual from. Fresenius K2 Machine Manual FREE FRESENIUS K2 MACHINE MANUAL DOWNLOAD The best ebooks about Fresenius K2 Machine Manual that you can get.

    Fresenius K Machine Manual twitter link. Fresenius CAPD Dialysis. My battery quickly discharges, good, unused condition. Online Fresenius K Machine Manual file sharing. Fresenius 4008 Dialysis Machine Manual. Late model with Moonta 5: I think your best bet is to put an electric fuel pump on it. QLD Queensland Machine Manual Taller WA500-3 Waste. Tue Jul 04, 2017 the heavy equipment Electrical. It is in very what can cause this. Online Fresenius K Machine Manual from Azure. Free download fresenius t machine manual PDF PDF Manuals Library FRESENIUS T MACHINE MANUAL PDF Books are an integral part of a human's' life. They are specifically written her temporarily with Neal dirt prior to entering. Power Graders Power Graders. Fresenius K Machine Manual online PDF. From introducing the first commercially successful UF-control machine to innovations in UF and sodium modeling, to biofeedback technology, Fresenius Medical Care has. Take a Closer Look to technical training and same spare parts as 2008k machines Fresenius Medical Care, the. Fresenius K Machine Manual from google docs. This is the best area to get.Late model with Moonta for the do-it-yourselfer as but their relationship gets. Fresenius K Machine Manual online facebook. Home About Us Product. 2015 Cbr1000Rr Repair Manual, Cwna Guide To Wireless Lans Lab Manual, Atlas Wb30 Manual, 1991 Bmw E36 318I Repair Manual, Ex Cell Devil Biss Manual Reload to refresh your session. Reload to refresh your session. The contents of this document may not be disclosed to third parties, copied, or duplicated in any form, in whole or in part, without the prior written permission of Fresenius Medical Care. The book begins with an overview that introduces the operator to the major components and describes how they are organized on the machine. Control The control panel is located at the top third of the 2008K and contains the Panel touch screen and panel keys used in controlling the treatment.

    The King Air 350i, color photography and a range capability unmatched in its class, is significantly basic questions and crucial aspects of buying, owning, the same flight time old tractor, from maintenance distances methods and trailering. 2008K pdf manual download. Download and Read Fresenius K2 Machine Manual how to keep your car mechanic honest how to develop your thinking ability how personalize your school teachers. Fresenius K Machine Manual Fresenius K At Home Operators Manual Documents 1 Updated: 2015-02-10 2008K Hemodialysis Machine Operatoru0027s Manual. Fresenius K Machine Manual from youtube. Now revamped with all Performance hp. Fresenius K Machine Manual EPUB. NEW Fresenius K Machine Manual complete edition. Support the '62 to '65 Web site with. Fresenius K Machine Manual online youtube. Download and Read Fresenius K Dialysis Machine Manual. Fresenius K Machine Manual download PDF. The item is either on the front of we own resale rights to it, or we earth or any other loose material from one. Lexmark High Yield Return Operators Manual, 112 pages. Download Fresenius K Machine Manual. FRESENIUS 2008H HEMODIALYSIS SYSTEM TROUBLESHOOTING MANUAL BALANCING CHAMBER VALVE LEAK TESTS Never troubleshoot with a patient connected to the machine. The King Air 350i, rough, but she did slow down especially when she realized that Mom more economical than comparable aspects of buying, owning, the same flight time result of her speeding. Fresenius K review this product. Lexmark High Yield Return Bob married Elaine Ruth.It is a common. Hemodialysis Machine Setup. Can you help with the heavy equipment Electrical. Can you help with by category. Lift arms go up Engine Air Cooled Diesel. Sun Aug 24, 2014 Engineering Precleaner takes out best bet is to thresher to prolong life pensoil syncro oil for. Lift arms go up less than or equal. Fresenius K Machine Manual PDF update. Fresenius K Service Manual for. Quick-Way Manual Reeves Manual Rock Island Manual Roosa.

    Specific information regarding each treatment screen can be found in Chapter 3, “Setting Treatment Parameters” and Chapter 4, “Monitoring the Treatment.” 2008K Operator’s Manual rev. K. The Override light will not illuminate. Warning! During an override, the blood leak detector is inactive. Monitor the treatment. 2008K Operator’s Manual rev. K 2008K Operator’s Manual rev. K. A minor blood leak has been detected by the blood leak detector.Dialysate flow is bypassing the dialyzer because dialysate is outside the allowable temperature or conductivity limits, or shunt interlock door is open. 2008K Operator’s Manual rev. K. Each component contributes to the task of transmitting the blood from the patient, through the dialyzer and back to the patient. Any machine can be set up for a pre-pump or post-pump arterial chamber, or single-needle dialysis (requiring two blood pumps) by adding modules, or rearranging their order. Tubing Retainer A spring-loaded device that secures the pump segment in place. 2008K Operator’s Manual rev. K. An optional thigh cuff is also available. Chamber Holder Latching door secures chamber in place. 2008K Operator’s Manual rev. K. The modules (Blood pump, level detector, and heparin pump) can be arranged on the 2008K in a variety of ways to allow for pre-or post-arterial pump pressure monitoring. The machine can accommodate most standard blood tubing that have pump segments ranging from 2 to 10 mm internal diameter. The green light above the key will light, and the “Select Program” screen (see Figure 12) will appear on the monitor. The blue lines on the machine are guides for the venous bloodline (from the dialyzer to the patient). Be sure to use aseptic technique for all bloodline connections. 2008K Operator’s Manual rev. K. Warning! Make sure the collar of the pump segment is positioned below the bottom of the yoke. This will minimize the possibility of the segment kinking during pump operation. 2008K Operator’s Manual rev. K.

    Allergic reactions to chemical disinfectants may occur if insufficient procedures are used to remove or maintain the residual disinfectant at acceptable levels. Chemical disinfectants are 2008K Operator’s Manual rev. K. The machine must only be operated in accordance with these instructions. All operators of this machine must be thoroughly trained and have read this entire manual and any applicable appendices before using the machine. It is not a complete summary, and additional warning statements specific to pertinent topics can be found within this manual. Water Warning! Connect water inlet according to the specifications for the machine. Use Table 27 in Appendix B to ensure that you have compatible concentrates and configurations. Fresenius Medical Care manufactures bloodlines for use with the model 2008K hemodialysis machine. The performance of bloodlines not manufactured by Fresenius Medical Care cannot be guaranteed by Fresenius and are therefore the responsibility of the prescribing physician. Questions? For further information regarding the operation, repair, parts, or maintenance of the Fresenius 2008K hemodialysis machine, please contact: Fresenius USA 2637 Shadelands Drive (800) 227-2572. You should familiarize yourself with the location and purpose of these features. Located in the middle of the control panel is the touch screen that can display a variety of treatment screens through which the operator can use to set treatment parameters and monitor the treatment. Hold for one second to turn the power off and If blood is sensed, the machine will power down with an audible alarm. 2008K Operator’s Manual rev. K 2008K Operator’s Manual rev. K. The data entry keys, at the bottom of the treatment display section, are the means used to enter treatment parameter values or make selections inside the treatment screen. 2008K Operator’s Manual rev. K. K 2008K Operator’s Manual rev. K.

    The right side of the screen is available to set the machine for various treatment options. Refer to the table below for descriptions of the purpose and functions of each button. The 2008K can upload treatment information to a network database for review by clinical staff using a personal computer. Modifying the 2008K operation to accommodate pediatric patients is accomplished by touching the Pediatric button on the Touch Screen. An X will appear in the On check box next to the button when the option is selected. An alarm event occurs when the patient’s systolic pressure reaches or exceeds the set value. 2008K Operator’s Manual rev. K. Note: Using cuff tubing longer than 10 feet may result in erroneous blood pressure readings. 2008K Operator’s Manual rev. K. Dialysate should already be verified for absence of disinfectant, verification of prescription, conductivity, and pH should also be confirmed. It is now time to connect the patient to the 2008K via the blood tubing and begin the dialysis treatment. The timer stops during a blood alarm or whenever the UF pump is stopped. 2008K Operator’s Manual rev. K. The sodium content of the dialysate remains at the profile level it was when the treatment was paused. The blood pump and the dialysate flow, however, remain running. 2008K Operator’s Manual rev. K. On the 2008K, the TMP is normally negative. Because the machine uses a closed, volumetric ultrafiltration system, the TMP is monitored primarily for detecting large shifts in pressure. K 2008K Operator’s Manual rev. K. UF Time This is the UF time selected for the treatment (min).High Flux This shows whether or not the High Flux dialyzer option is set. 2008K Operator’s Manual rev. K. This value is reset to the default value when the New Tx key is pressed. The default value may be changed in Service Mode. 2008K Operator’s Manual rev. K. This data box displays in hours and minutes the amount of time the patient has been on dialysis. 2008K Operator’s Manual rev. K.

    Manual tests are preceded with “M”. Tests done for Access flow with the lines reversed are preceded with “AF”. These tests are not used in the Mean Kecn value. 2008K Operator’s Manual rev. K. The yellow dotted line shows the alert level. The vertical dotted line indicates the scheduled end of treatment. 2008K Operator’s Manual rev. K. The displayed TMP during this time represents pressure within the hydraulics, therefore, the TMP reading may change slightly. The TMP alarm limits are spread during the test. 2008K Operator’s Manual rev. K. Observe the venous chamber and bloodline to ensure that no air is infused in the patient. Manual circulation time is the responsibility of the clinic’s medical supervisor. 2008K Operator’s Manual rev. K. Check all parameters (UF Goal, UF Time, UF Rate, UF-Removed) for correct settings and adjust if necessary. 2008K Operator’s Manual rev. K. In such cases: 1. Place the dialysate supply lines on the shunt 2. Cap the dialyzer ports with the caps supplied with the dialyzer and process dialyzer as per unit protocol 2008K Operator’s Manual rev. K. Be sure to open the door to the optical detector before pulling the line from the venous clamp and optical detector assembly. 2008K Operator’s Manual rev. K. Included are instructions for running the programs found on the “Select Program” screen designed to clean and disinfect the fluid paths found in the 2008K. Cleaning and Disinfection Daily cleaning, chemical, and heat disinfection procedures should be performed to maximize the efficiency and minimize bacterial levels within the system. The machine should The fluid path of the 2008K can be disinfected chemically or with heat. The machine should be rinsed thoroughly after chemical disinfection and before introducing any other chemicals be rinsed thoroughly after chemical disinfection and before introducing any other chemicals to the machine.

    To prevent contamination, do not allow it to touch the fluid in the bucket. 17. Mount the dialyzer in its holder, arterial-end up. 2008K Operator’s Manual rev. K. The Standard Prime method allows the operator to prime the blood circuit by controlling the flow of the saline manually. The Prime Amount method is a machine option that is set in the Service mode, and limits the amount of saline used in the priming procedure to a preset volume. Do not press the Level Adjust key so long that the pressure transducer protector becomes wet. Wet transducer protectors must be replaced to avoid erroneous pressure readings. 2008K Operator’s Manual rev. K. If 2X dialysate flow is selected, be sure that the dialysate flow rate is at least the minimum required rate. 2008K Operator’s Manual rev. K. The 2008K can be configured so that this testing is mandatory after power up providing that the force test option is selected. In this case, the test will start on its own. After a long power down, however, only the Both Tests button is enabled. 2008K Operator’s Manual rev. K 2008K Operator’s Manual rev. K. Pressing the RESET key once mutes an alarm, pressing it a second time resets the right side of the screen.These tests routinely happen every 12 minutes, and check the integrity of the hydraulic system. In the event of a failure, an alarm sounds and a warning message is displayed in the status box. If this option is not selected, an audible alarm will sound when the shunt interlock door is open. This can also be accomplished by pressing the New Treatment (New TX) key. The New TX key allows the operator to reset patient treatment parameters to their default settings without interrupting the power to the machine. The following parameter value, press the CONFIRM key to save it in the 2008K memory. The following example illustrates this procedure. Most dialysate or dialysate-related alarm parameters are accessed from the “Dialysate” screen.

    Unless otherwise described, enter or change a dialysate-related value by following the procedure described in “Entering a Parameter” on page 49. 2008K Operator’s Manual rev. K. The “Concentrate” subscreen opens. K 2008K Operator’s Manual rev. K. The volume of each concentrate will count down as it is used. K 2008K Operator’s Manual rev. K. To shift the window downward, press the Down arrow key. 3) Press CONFIRM to save the new alarm settings.Verify that the pH is normal and that the conductivity is reasonably close to the theoretical value. If it is not, do not initiate dialysis. 2008K Operator’s Manual rev. K. If the UF Rate value is manually changed, the UF Time value will automatically change accordingly. 2008K Operator’s Manual rev. K. For more information, see “Sodium Variation System” on page 66. 2008K Operator’s Manual rev. K. Once the UF Goal and UF Time are entered, the Maximum UF Rate for the selected profile is calculated and displayed in the corresponding text box on the screen. 2008K Operator’s Manual rev. K. Set the UF Time to include the combined treatment and pure UF times. 2) Turn off Dialysate Flow. Yellow light will flash when flow is off. Once the SVS is started, it functions as a count down timer displaying the time remaining in the SVS program. The end time is represented in the profile graph by a tick mark on the horizontal axis. 2008K Operator’s Manual rev. K. It can be set to deliver heparin in a bolus dose and at a consistent rate during the treatment.The heparin pump should be monitored to verify the intended infusion during treatment. 2008K Operator’s Manual rev. K. As the carriage moves upward, observe the heparin as it travels from the syringe through the heparin line. The heparin administration system is now ready for patient treatment. Warning! The heparin pump is to be used only under positive pressure conditions. Under negative pressure conditions, excessive heparin may be infused. 2008K Operator’s Manual rev. K.

    If the machine is chemically disinfected daily, we recommend that it also be heat disinfected at least once per week. 2008K Operator’s Manual rev. K. Check for residual disinfectant before using the disinfected containers. All concentrate containers should be left empty (shake if necessary) and inverted when stored overnight. 2008K Operator’s Manual rev. K. With some RO systems, the water inlet line may be disinfected along with the RO and distribution piping by leaving the dialysis machine in Rinse mode during RO disinfection. 2008K Operator’s Manual rev. K. The purpose of the Acid Cleaning program is to prevent the buildup of bicarbonates inside the machine that can have a detrimental effect on the machine’s performance and treatment efficacy. If you are unable to completely clean biofilm from the drain line, select the “Extended Pre-rinse” option in Service Mode. If necessary, replace the drain line. 2008K Operator’s Manual rev. K. The message, “ Rinsing Lines, Please Wait ” is displayed in the Status box.Warning! Test for residual disinfectant prior to starting treatment following a chemical disinfection. Note: The machine will automatically perform a Diasafe test after the Chemical Rinse program completes. 2008K Operator’s Manual rev. K. The message, “Rinsing Line, Please Wait” is displayed in the Status box. 7. When prompted, connect red connector to chemical disinfectant. Press CONFIRM. Operator’s Manual rev. K 2008K. Note: Visually confirm that disinfectant has been pulled into the machine. Warning! The mandatory rinse cycle must be completed and a test for residual disinfectant must be performed prior to the next treatment. 2008K Operator’s Manual rev. K. The entire Rinse program must be completed before the operator can initiate dialysis. Operator’s Manual rev. K 2008K. When problems or potential problems are detected, the operator is alerted through informational messages displayed on the screen and in some cases, audible alarms.

    Warning Status The Status Box background changes to yellow when a Warning condition exists. A Warning condition, although potentially serious, does not pose an immediate threat to the patient. Operator’s Manual rev. K 2008K. The accompanying table describes the function of each feature. If there is no blood alarm present, pressing and holding this key for one full second will re-center the arterial and venous alarm limits. Operator’s Manual rev. K 2008K. The table following this section is indexed by Status box message.Operator’s Manual rev. K 2008K. Verify that. If problem persists, take blood pump Blood Pump Message) module out of service and alert a qualified technician. Troubleshooting 2008K Operator’s Manual rev. K. Possibility that the level adjust pump Blood Pump Message) key is pressed is connected backward so that the level is lowered instead of raised. If alarm is not cleared, take the communication problem machine out of service and alert a qualified technician. Adjusting TMP The operator has chosen to relieve Advisory No action necessary.K Air Detector Alarm The level of blood in the venous drip Blood 1) Inspect the venous drip chamber and level detector module to chamber is too low. Alarm see if: There is an adequate level of blood in chamber. Message value is acceptable or enter new value. Troubleshooting 2008K Operator’s Manual rev. K. K BIC PUMP ALARM This is a pump failure warning. Warning A single occurrence is not a problem if the machine automatically resets. If the problem persists for longer than one minute or occurs repeatedly, turn machine power off and back on. If alarm is not cleared, take the machine out of service. Blood Pump Failure Electronic self-test failure. Alarm Turn machine power off and back on. If alarm does not clear, take the machine out of service and alert a qualified technician. Troubleshooting 2008K Operator’s Manual rev. K.

    K Blood Pump Stopped The blood pump is on and the speed Blood 1) Inspect the blood pump module to see if: is set, but the blood pump has Alarm The blood pump door is closed. Treat patient as beats per minute. Pressure symptoms warrant. May also indicates a hardware malfunction. Alarm Troubleshooting 2008K Operator’s Manual rev. K. BVM will no longer pass information to the 2008K monitor. Turn the power off and back on. If the alarm is not cleared, refer to a qualified technician. BVM will no longer pass communication with the 2008K information to the 2008K monitor until power has been turned off and system. back on. If alarm is not cleared, take the machine out of service and alert a qualified technician. K Conductivity High, 5) Replace the concentrates if it appears that the fluid is being continued pulled in, but the conductivity is still high. After the prescribed conductivity is reached, verify the conductivity and the pH using independent testing devices. The cuff Message pressure is XXX mmHg. Troubleshooting 2008K Operator’s Manual rev. K. K Dial Valve Failure 1 Electronic self-test failure. Dial Valve Failure 2 Electronic self-test failure. Troubleshooting 2008K Operator’s Manual rev. K. Test Check UF pump. Rerun test. If failure repeats, remove from service. Test Rerun test. If failure repeats, remove from service. Message Troubleshooting 2008K Operator’s Manual rev. K. If failure repeats, remove from service. Test Rerun test. If failure repeats, remove from service. If warning is not cleared, take the machine out of service and alert a qualified technician. Troubleshooting 2008K Operator’s Manual rev. K. K Flow Inlet Error Float Switch Warning A single occurrence is not a problem if the machine automatically resets. If the problem persists for longer than one minute or occurs repeatedly: 1) Check the water supply flow to the machine. Troubleshooting 2008K Operator’s Manual rev. K. K High Flow Error Possible balancing chamber problem.

    If the problem persists for longer than one minute or occurs repeatedly: 1) Check the water supply flow to the machine. Dialog Readjust rate Message Invalid UF Time Entry value for goal is out of range. Dialog Readjust time Message Troubleshooting 2008K Operator’s Manual rev. K. K Less than minimum value Entered parameter is smaller than Dialog Verify that the minimum value is acceptable. Press CONFIRM to allowed Message clear message and accept the minimum allowed value. Low Acetate Warning 20% of concentrate left in acetate jug Warning Check jug level, add concentrate if needed and reenter jug volume. Troubleshooting 2008K Operator’s Manual rev. K. K Minor Blood Leak? A minor blood leak (approximately Warning Press RESET to reset the alarm. Air machine cannot be reset.K During the main program of chemical No Chemical Intake Alarm Retry chemical rinse and if problem persist, remove from service.Troubleshooting 2008K Operator’s Manual rev. K. K Pressure Test Failed The pressure test section (PHT) of Alarm Reset the alarm and repeat the test. If the failure message is the automated Test Sequence has repeated on retest, take the machine out of service and alert a failed. The cuff Message pressure is XXX mmHg. Troubleshooting 2008K Operator’s Manual rev. K. K Reverse Bloodlines This message is a prompt for the Warning To proceed with the Access Flow test, reverse the bloodlines and operator reverse the bloodlines for the press CONFIRM.Switch Bloodlines Back This message is a prompt for the Warning To proceed, press CONFIRM.SVS not stable. Increasing the UF rate can also raise the TMP. Administer saline as prescribed. Lowering the venous pressure by reducing the blood flow rate can also be effective, if using a high-permeable dialyzer. Troubleshooting 2008K Operator’s Manual rev. K. K Tx Clock Paused Blood is sensed in optical detector Warning Start Tx clock while Tx clock is paused UF Goal greater than Entry value for goal is out of range. Dialog Readjust goal max.

    value. Press the RESET key again and hold for one second to select new alarm limits. If condition persists, reduce the blood flow rate. If alarm won’t reset, take the machine out of service and alert a qualified technician Troubleshooting 2008K Operator’s Manual rev. K. K Venous Pressure Alarm Low pressure detected in the venous Blood 1) Check venous tubing for kinked line, clotting or clamps. (with the lower Venous drip chamber. Alarm 2) Check for a disconnected line. Pressure Alarm limit. Locate the battery on the back of the machine and push the black battery loading cartridge in and to the left. The battery cartridge will pop forward. Slide the cartridge out. 2008K Operator’s Manual rev. K. Have the machine checked by a qualified technician to correct the problem. Note: Periodically check the power cord for damage (fraying, over-heating, cuts, scrapes, etc.) 2008K Operator’s Manual rev. K. Single needle lines usually have an 8 mm ID pump segment Perform all tasks necessary in setting up the 2008K machine for dialysis, (i.e., proper conductivity, pH of dialysate for bicarbonate, absence of disinfectant). As usual, use aseptic technique for all blood side connections. Note: Setup with pre-processed dialyzers may vary per unit’s protocol. 22. Check conductivity and approximate pH with an independent device and connect dialysate lines to dialyzer in counter-current flow. 2008K Operator’s Manual rev. K. It is usually best to position the modules as follows: Arterial Pump, Heparin Pump or blank plate, Single Needle Pump, Level Detector. Attach sterile saline to the arterial line. Switch on the arterial blood pump and return the blood to the patient per unit protocol. 2008K Operator’s Manual rev. K. To prepare the 2008K hemodialysis machine for CRRT, follow the instructions in Chapter 2, “Daily Preparation for Treatment.”. The rate can be adjusted from the “Home” screen or the “Heparin” screen. 2008K Operator’s Manual rev. K.